Call for Price!

4HP (GACHDPA) / 4HVP (GACHBPA) Sutorbilt Legend Blower
[TS-GD-4HP]

4HP (GACHDPA) / 4HVP (GACHBPA) Sutorbilt Legend Blower
Page title

The Sutorbilt blower operates by trapping air with two "figure eight" impellers rotating in opposite directions. This entrapment occurs four times per revolution and efficiently creates pressure and volume for your aeration system.

The Sutorbilt Legend Series features machined cast iron construction of the housing and impellers. Impellers are dynamically balanced to operate without vibration and are permanently fastened to steel shafts. Shaft rotation can be in either direction. To change the inlet/discharge orientation of the blower simply reverse the rotation of the drive motor.

Anti-friction bearings are used throughout. Timing gears and gear end bearings are splash oil lubricated from an oil-tight housing enclosing the timing gears. Drive end bearings are grease lubricated through fittings. High temperature Viton lip type seals prevent the oil and grease from entering the impeller chamber to prevent contamination in your system.

Sutorbilt Legend Pressure Performance Data
Size Dia. Inlet & Outlet RPM 7 PSIG 8 PSIG 9 PSIG 11 PSIG 13 PSIG 15 PSIG
CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
4HP 4HVP
1-1/2" - S
1,760
80
4.0
77
4.6
74
5.2
2,190
110
5.0
107
5.7
104
6.4
99
7.9
2,620
139
6.0
137
6.9
134
7.7
129
9.4
124
11.1
3,600
207
8.2
204
9.4
201
10.6
196
13.0
192
15.3
188
17.7
S = Threaded connections standard NPT. F = Flange connections.

Performance based on standard conditions: Sea Level, 14.7 PSIA, 68°F, 36% Relative Humidity.

For performance with gases other than air or at non-standard conditions, contact Tri-State Wastewater Equipment's customer service by email at: info@tri-statewastewater.com, by phone at: 513-342-1668, or by fax at: 513-334-0222, and we would be happy to help with any questions or sizing information.


HORIZONTAL CONFIGURATION





SizeWt.Conn.ABCDEFGHJKLMNOPRSTU
4HP1381-1/2 - S7-1/43384-3/166-1/4410-7/1612-3/81-1/26-7/813-3/442-3/82-1/83/160.8753/81/2x3/4
S = Threaded connections standard NPT. F = Flange connections. Inlet and outlet connections are the same type and size.
Dimensions are in inches. Weights are in pounds and include factory shipping cartons or pallets. (Actual shipping weight may vary)

VERTICAL CONFIGURATION





SizeWt.Conn.ABCDEFGHJKLMNOPRSTU
4HVP1381-1/2 - S7-1/43384-1/26-1/28-1/212-11/168-3/81-1/26-7/813-3/442-3/82-1/83/160.8753/81/2x3/4
S = Threaded connections standard NPT. F = Flange connections. Inlet and outlet connections are the same type and size.
Dimensions are in inches. Weights are in pounds and include factory shipping cartons or pallets. (Actual shipping weight may vary)

The Flex-Mount design makes it easy to change from a right hand drive to a left hand drive on the horizontal unit by unbolting the feet and rotating the blower 180°. To change a bottom hand drive to a tip hand drive on a vertical unit, simply rotate the blower 180°. To quickly convert a horizontal blower to a vertical (90° rotation), simply bolt on a set of vertical mounting feet (sold separately). The plane of the shafts determine whether a blower is vertical or horizontal, not the inlet and outlet ports. Be sure to torque bolts down and reverse the oil drain and fill plugs. Inlet/discharge pipe connections are the same size, female NPT.
We Accept
1 x LP4185 22" Ultraviolet Lamp, 1 Pin Each End
1 x Wiper Blade for Sunlight Systems SL160
1 x LP4040 33.2" Ultraviolet Lamp, 1 Pin Each End
1 x LP4825 17" Ultraviolet Lamp, 3-1 Step
2 x Fiberglass Enclosure Exhaust Fan Installed Adder
2 x Medium-Wide Fiberglass Blower Enclosure Noise Suppression Adder
1 x LP4055 33.2" Ozone Ultraviolet Lamp, 4 Pin Flat
1 x LP4115 14" Ultraviolet Lamp, 2/2 Pin Step
1 x LP4425 14.25" HO Ultraviolet Lamp, 4 Pin Flat
2 x Medium Fiberglass Blower Enclosure Noise Suppression Adder
2 x Norweco AT1500 UV Power Cable with Female Connector
1 x O-Ring for Sunlight Systems SL160
2 x 1" Thick Noise Suppression Panels 2ft. x 4ft., Qty 4
1 x Wiper Nut for Sunlight Systems SL160
1 x LP4395 33.2" Ultraviolet Lamp, 3-1 Step
1 x LP4095 17" Ultraviolet Lamp, Mini Bi-Pins Each End
2 x Small Fiberglass Blower Enclosure Noise Suppression Adder
1 x LP4130 11.29" Ultraviolet Lamp, 1 Pin Each End
1 x LP4435 33.2" HO Ultraviolet Lamp, 3-1 Step
1 x End Plug Assembly
1 x 3VX Notched V-Belt 3VX315
1 x LP4165 14" Ultraviolet Lamp, 1 Pin Each End
1 x Medium Fiberglass Blower Enclosure Model TS-FIB-M
1 x LP4290 17" Ultraviolet Lamp, 4 Pin Flat
1 x Compression Nut
1 x LP4110 14.25" Ozone Ultraviolet Lamp, 4 Pin Flat
1 x LP4305 31.88" Ultraviolet Lamp, 4 Pin Flat
1 x LP4020 61.2" Ultraviolet Lamp, 4 Pin Flat
1 x Norweco Blue Crystal Disinfecting Tablets 5# Pail
1 x Large Fiberglass Blower Enclosure Model TS-FIB-L
1 x LP4085 25.5" Ozone Ultraviolet Lamp, 4 Pin Flat
1 x LP4150 11.29" Ultraviolet Lamp, Mini Bi-Pins Each End
1 x LP4945 60" Amalgam Ultraviolet Lamp, 4 Pin Flat
1 x Norweco Model AT 1500 Ultraviolet Disinfection System
1 x GPH450 17.72" OZone Ultraviolet Lamp, 4 Pin Flat
1 x Norweco AT1500 UV Lamp
1 x LP4260 18" Ultraviolet Lamp, 4 Pin Flat
1 x LP4030 61.2" Ultraviolet Lamp, 2/2 Pin Step
1 x LP4420 33" HO Ultraviolet Lamp, 4 Pin Flat
1 x LP4090 18" Ozone Ultraviolet Lamp, 4 Pin Flat
1 x Wiper O-Ring
1 x Small Fiberglass Blower Enclosure Model TS-FIB-S
1 x LP4775 33" Amalgam Ultraviolet Lamp, 3-1 Step
1 x LP4050 33.2" Ultraviolet Lamp, 4 Pin Flat
1 x LP4390 61.2" HO Ultraviolet Lamp, 3-1 Step
1 x Medium-Wide Fiberglass Blower Enclosure Model TS-FIB-MW
1 x O-Ring for Q-020833
1 x LP4060 33.2" Ultraviolet Lamp, 2/2 Pin Step
1 x O-Ring
2 x Large Fiberglass Blower Enclosure Noise Suppression Adder
1 x Norweco Bio-Perc Remediation 12 Pods
1 x LP4440 61.2" HO Ultraviolet Lamp, 3-1 Step
1 x LP4695 31.88" Ultraviolet Lamp, 3-1 Step
1 x LP4105 14.25" Ultraviolet Lamp, 4 Pin Flat